Residential Fire Suppression System – Low Pressure Water Mist

2016-06-13:  Further to the Urgent Fire Safety Recommendations in Modern High-Performance Housing (posted on 2016-04-11) … this is what a Residential Fire Suppression System would look like in a Notional Detached House, and what it would cost …

Colour image showing the ground floor view of a Notional 2 Storey / 4 Bedroom Detached House. The pressurized 300 litre water cylinder is stored in the Garage.
Colour image showing the ground floor view of a Notional 2 Storey / 4 Bedroom Detached House. The pressurized 300 litre water cylinder is stored in the Garage. Click to enlarge.

Detached House – Ground Floor Plan – Ceiling Head/Nozzle Layout (PDF File, 97 Kb)

Detached House – Upstairs Plan – Ceiling Head/Nozzle Layout (PDF File, 13 Kb)

Pipework Installation
Water Mist Pipework Installation. Click to enlarge.
Mist Ceiling Head/Nozzle
Water Mist Ceiling Head/Nozzle. Click to enlarge.

.

Low Pressure Water Mist Fire Suppression System

Water flow rate = 13.94 litres per nozzle per minute.  Pressurized 300 Litre Water Cylinder, with BurnStop environment-friendly additive, supplies water to the low flow rate, CPVC (Chlorinated Polyvinyl Chloride) pipe network serving 25 Mist Ceiling Heads/Nozzles fixed at pre-determined locations.  See Plans.  Water runtime is 10 minutes, between 2 heads operating simultaneously without any mains water backup.  Installation takes 3 days in total (2 days first fix, plus 1 day second fix and commissioning).

The mains water supply system in Ireland is not reliable.

A water mist system or a sprinkler system ?

Cost for the above Notional Water Mist Installation is €7,340.00 (Euros) / £5,676.00 (British Pounds) – plus VAT.  This price is on the basis as a one-off installation in Ireland.  If a number of properties require installation at the same time, then travel costs are dispersed and the individual price per property is significantly reduced.

In a Terrace of Houses, where there is a Timber-Framed Party Wall between each house ... a Residential Fire Suppression System MUST be installed in ALL houses to be effective in each single property.
In a Terrace of Houses, where there is a Timber-Framed Party Wall between each house … a Residential Fire Suppression System MUST be installed in ALL houses to be effective in each single property.

.