LEED, PassivHaus & BREEAM Housing ~ Atrocious Fire Safety !!

2016-04-11:  It Happened One Night !

And Maybe … if it hadn’t been that particular night, during all the festivities of New Year’s Eve 2015, we would never have heard about the Address Supertall Hotel Fire, in Dubayy (UAE).  A long search on the Internet afterwards led to the detailed, post fire analysis report on the 2014 Lacrosse Docklands Fire, in Melbourne (Australia) … followed by some more searching, and a very large can of worms opened up … similar nasty façade (external fabric) fires in many, many countries … involving large chunks of flaming debris falling from terrific heights, carried by the wind to a significant distance away from the building of fire origin.

Click to enlarge.
Click to enlarge.

Some people have tried to suggest that the only reason for these fires is inadequate building codes/regulations.  No … the reason for these fires is much more than that … it’s the ‘SYSTEM’ !   In other words, how the International Construction Sector is organized and goes about its ordinary, everyday activities and tasks.  We must also talk about poor quality design and construction … and a lack of stringent, independent enforcement of effective building codes/regulations and standards.  I have written this down many times before … Self-Regulation is NO Regulation !!

It is very clear that Conventional Fire Engineering … as currently practiced, internationally … is no longer ‘fit for purpose’.  For discussion at SFE 2016 DUBLIN.  Check out the Fire Conference Website: www.sfe-fire.eu … and on Twitter: @sfe2016dublin

.

IN IRELAND … A 2015 TERRACED HOUSING FIRE …

The general public was shocked and stunned, to put it mildly, by a very rapid and extensive 2015 Terraced Housing Fire on the outskirts of Dublin …

Click to enlarge.
Click to enlarge.

[ See my Blog, dated 2011-04-06 … about a different, but related, 2011 Terraced Housing Fire in Terenure, a suburb of Dublin City.]

Click to enlarge.
Click to enlarge.

[ Fast forward from 2011 … overtaking Priory Hall (see my series of Blogs) … to Longboat Quay, a large residential development on the south bank of the River Liffey, which flows through the middle of Dublin.  A recent visual/surface inspection of one of the units there revealed not just a poor quality of construction … but a lack of care and attention, with a mixture of incompetence and ignorance thrown in for good measure.]

Click to enlarge.
Click to enlarge.

The 2015 Terraced Housing Fire, shown above, should not have been a surprise to the ‘System’ in Ireland.  Research carried out in the U.S.A., Belgium and The Netherlands since 2012, and a serious PassivHaus Apartment Fire in Köln, Germany, on the night of 5 February 2013  … have all shown that the modern home (highly insulated, airtight, packed with electronic equipment and wiring, and fast-burning synthetic furnishings, etc.) is the ‘perfect storm’ of fire conditions and outcomes.  More open residential design + increased fuel loads + new construction systems and materials = faster development of fires, much reduced times to flashover, far less time for occupant evacuation, particularly people with activity limitations … and shorter building collapse times.

The time to flashover in modern high-performance housing, i.e. Sustainable/Green/PassivHaus/Eco/LEED/Bio/+Energy/Low Carbon/BREEAM/Zero Carbon/SMART … can be 7 times faster than in conventional/legacy housing … or less than 5 minutes, compared with just over 29 minutes !

All of this research can be found on the Links & Docs Page of the SFE 2016 DUBLIN Website.

Let us be crystal clear … there is nothing Sustainable/Green/PassivHaus/Eco/LEED/Bio/+Energy/Low Carbon/BREEAM/Zero Carbon/SMART about the post-fire scenes of destruction shown above.  And only for the physical separation between terraces, which can be clearly seen in the last photograph … the fire would have kept spreading.

.

URGENT FIRE SAFETY RECOMMENDATIONS …

Without a balanced, proper approach to the issue of Fire Safety in this type of modern, high-performance housing … occupant safety is seriously threatened.  And if, in the event of a fire incident, the occupants are asleep … or people with activity limitations are living in the house … that threat will be extremely grave indeed.

Reality – Reliability – Redundancy – Resilience !

So … what needs to change ?   In Ireland, our immediate problem is Timber-Framed Housing (as shown above) … and the following is an outline of what must change … NOW !

  1. Party Walls, i.e. the walls separating one house from another, must be constructed of solid masonry, with a uniform and uncompromised thickness of at least 200mm … plastered on both sides, not dry-lined, for adequate smoke resistance … and be continued above the roof covering for at least 300mm.
  2. An effective Fire Detection System must be installed.  The conventional ‘package’ of one smoke detector per floor in the hallway and staircase of a standard 2 storey semi-detached house is nowhere near being adequate.
  3. An effective Residential / Domestic Fire Suppression System must be installed, e.g. low pressure water mist.  See later post, dated 2016-06-13, for a costed notional installation.
  4. If there is a Controlled Ventilation System, either mechanical or natural, in the house (for the purposes of air quality, heat exchange and energy conservation), it must be linked to the fire detection system.  In the event of a fire incident, the Ventilation System must immediately cease operation, and remain ‘fully open’.  This is in order to mitigate the build-up of high positive pressure, within a confined airtight space, caused by a developing fire … and to provide an exhaust route for smoke and toxic gases … during the short period of time prior to activation of the fire suppression system.
  5. Intermediate Timber Floors and Evacuation Routes, including fire resisting doorsets, must be reliably protected from fire and smoke.  The minimum period of fire and smoke resistance must be linked to local fire service support infrastructure.  In other words, the local fire services must be allowed sufficient time to arrive at the scene of a fire in strength … to search for any occupants still remaining in the fire building … and to bring the fire under control.
  6. Uppermost Ceilings under a trussed timber roof structure, including any trap doorsets into the roof space, must be similarly and reliably protected from fire and smoke.  Once fire enters a roof space, the light trussed timber structure will collapse within a few minutes.
  7. Front and Back Entrance/Egress Doors must be outward opening.  In the 2013 German PassivHaus Apartment Fire, the occupant found it extremely difficult to open inward opening doors and windows because of the high positive pressure caused by the developing fire.  This unusual phenomenon was confirmed in the 2015 Finnish Apartment Fire Tests, when much higher positive pressures were observed.
  8. Internal Linings of External Walls must comprise 2 layers of plasterboard, with all joints staggered … steel fixed, at not more than 150mm centres.  Once fire breaches the internal lining of an external wall, the whole building will become involved in the fire.  Horizontal and vertical fire sealing behind these linings, even if properly installed (!), are too little and too late.
  9. Frontline Firefighters must be supported by specialist structural engineering and hazard appraisal units … and light/portable/reliable Thermal Imaging Cameras must be recognized as a standard tool of firefighting.

.

SUSTAINABLE HOUSING & RESIDENTIAL BUILDINGS …

These building types are more popularly known as Green, PassivHaus / Passive House, LEED, Eco, Bio, BREEAM, +Energy, Zero / Low / Nearly Zero Carbon, or SMART, etc., etc, etc.   In ALL of these cases, however, an Effective Residential Fire Suppression System MUST BE INSTALLED, e.g. low pressure water mist !

In everyday practice … Authorities Having Jurisdiction (AHJ’s), and the Organizations and Individuals responsible for the far-too-rapid construction of these innovative building types are either completely and blissfully ignorant, or callously and negligently in denial, about the seriously negative impacts on Occupant & Firefighter Fire Safety and Building Fire Protection.

BUT … slowly … more and more reliable evidence is being gathered !   Please visit the Links & Docs Page on: www.sfe-fire.eu … and also view this Presentation on some very interesting 2015 Apartment Fire Tests in Finland: www.youtube.com/watch?v=0Ss_ONolzLY

.

ENERGY CONSERVATION & EFFICIENCY UPGRADING OF EXISTING BUILDINGS …

In refurbishment projects where insulation is fixed to the internal surfaces of external walls … similar fire safety problems exist, and they must be solved by reviewing the full checklist above.  Refer again to the PassivHaus Apartment Fire in Köln, Germany, on the night of 5 February 2013 … and to the 2015 Apartment Fire Tests in Finland

.

.

END

‘Passivhaus’ Standard is Not Enough in New Building Projects !

2013-09-10:  Recently, much ado has been made in the technical press about a New Multi-Storey Office Block in Vienna which has achieved the German ‘Passivhaus’ (Passive House) Standard

Multi-Storey 'RHW.2' Office Block in Vienna, Austria

Is There A Problem ??   Yes !!

1.   It takes approximately 3 Years of Building Occupation, by ‘real’ people, before the actual performance of a building can be properly monitored and reliably shown.  The building is still ‘drying out’ for the first year.  It takes at least one to two years of running the complex technologies and systems in today’s buildings … training people how to operate them efficiently and effectively … and fine-tuning and de-bugging as you go along … before everything begins to work together, as originally intended during the building design stage.  Then, if all goes well … in the third year of occupation, the careful (i.e. accurate and reliable) monitoring of ‘real’ building performance, by means of portable measuring devices and devices installed within the construction, can commence.

So … what exactly has achieved the German ‘Passivhaus’ (Passive House) Standard … the design intent for the building, or the building’s ‘real’ performance ???

.

2.   Much more fundamentally … achieving this Standard is a good starting point … but in a new building project … It Is Not Enough !

A.  Energy Conservation and Efficiency Burden Sharing by Different Building Types

Separate strategies are required to greatly improve the energy performance of:

  • existing buildings … onto which many energy efficiency measures can be successfully grafted, but it will be difficult work and will certainly not be cheap ;
  • buildings of historical, architectural or cultural importance … the integrity of which must be protected ;   and
  • new buildings and facilities … which must therefore carry the major burden.

.

B.  Paradigm for New Buildings – A ‘Positive Energy’ Return + Assured Building User Comfort

Primary Energy Consumption should be less than or equal to 15 kWh/m2/yr.

And …

Renewable Energy and Heating Systems should contribute a reliable quantity of energy, per year, which covers the following:

i)   the Building’s/Facility’s Primary Energy Consumption ;

ii)  an Energy Efficiency Degradation Factor which takes account of the degradation in energy efficiency …

(a)  normally expected during the life cycle of renewable energy and heating systems installed in the building.  The rate of degradation will depend on the quality of maintenance and servicing ;   and

(b)  caused by wasteful patterns of building management and/or use ;

iii) the energy consumed by Private Transport associated with the building or facility ;

iv) an Energy Return to an Intelligent District, Local or Regional Grid exceeding, by a multiple of 3 (three), the total energy consumed by the Building/Facility (including its Energy Efficiency Degradation Factor) and any associated Private Transport.

.

Notes:

Primary Energy includes the energy required to generate, transmit and distribute electricity, as well as energy directly consumed on site.

User Thermal Comfort = Air Temperature + Mean Radiant Temperature + Air Humidity + Air Velocity, i.e. draughts (ISO 7730).

.

And interestingly enough … on the Passivhaus WebSite (German language version)www.passivhaus.de/passivhaus-informationen/vom-passivhaus-zum-plusenergiegebaeude.html … this is now the thinking there also !!

Should have been happening 10 years ago !

.

.

END

Enhanced by Zemanta

Upcoming Building Research Workshop at Galway University

2013-06-08:  Looking forward to some serious, collaborative and multi-disciplinary discussions on the day … and a barrel of laughs in the process (!!) …

The Informatics Research Unit for Sustainable Engineering (IRUSE) in the Department of Civil Engineering … and The Ryan Institute for Environmental, Marine and Energy Research … both at the National University of Ireland Galway (NUIG) … have jointly organized a 1-Day National Research Networking Workshop which will take place on Monday, 24 June 2013.

The NUIG ‘blurb’ for the day states … “Considering the importance of aggressive energy-efficiency measures in the Building Sector, together with the requirements for a safe, healthy, comfortable (and accessible) Built Environment … this NUIG Workshop will explore the topic of Integrated Modelling and Performance of the Built Environment.”

.

I was very pleased to receive an invitation to make a Presentation at this prestigious event …

‘Sustainable Fire Engineering Design’  –  My Presentation Abstract

Fire Engineering … involves much more than mere compliance with building regulations and codes … whose fire safety objectives are limited, and whose performance requirements are sometimes inadequate and always minimal.  More problematically … a fundamental conflict is mushrooming between Safe Sustainable Climate Resilient Building Design and Conventional Fire Consultancy Practice.

However … Sustainable Fire Engineering Design Solutions are:

  • Reliability-based ;
  • Person-centred ;

and above all

  • Adapted to Local Context and Heritage (fr: le Patrimoine – see ICOMOS 2011) … geography, climate (incl. change, variability and severity swings), social need, culture, and economy, etc., etc.

This Presentation will discuss very rich collaborative research potential in the following areas …

  1. Creative Fire Engineering Concepts and Building Systems
  2. Fire-Induced Progressive Damage in Buildings
  3. Human Behaviour and Abilities in a Fire Situation
  4. Building Design for Firefighter Safety
  5. BMS – Fire Modelling – BIM

Research Output must be targeted at practical implementation in ‘real’ buildings … with actual user/construction performance carefully (i.e. reliably and precisely) monitored !

.

If anybody out there is interested in attending this NUIG Research Workshop … please contact Ms. Magdalena Hajdukiewicz (IRUSE) at: hajdukiewicz1@nuigalway.ie

.

.

POST-EVENT UPDATE:  2013-06-27 …

While it was difficult to keep the Workshop Programme, involving a series of short 10-minute presentation slots, on track … discussions during the day were engaging, energetic and extensive.

I happily look forward to a successful and collaborative outcome from the day … Multi-Disciplinary Teams producing Trans-Disciplinary Research Output … which is geared towards practical implementation in ‘real’ buildings, with actual construction and building user performance carefully (i.e. reliably and precisely) monitored !

Galway University (NUIG) Workshop Programme & Presentation Abstracts

Click the Link Above to read and/or download PDF File (193 Kb)

Galway University (NUIG) Built Environment Research Networking Workshop - 24 June 2013
Colour photograph showing the venue for the IRUSE & The Ryan Institute (Galway University – NUIG) Built Environment Research Networking Workshop, which was held in the New Engineering Building on 24 June 2013. Seen here is Dr. Harald Berresheim during his presentation on ‘The Self-Cleansing Capacity of Our Atmosphere – Limitations on Local to Global Scales’. Photograph taken by CJ Walsh. 2013-06-24. Click to enlarge.

.

CJ Walsh Presentation: ‘Sustainable Fire Engineering Design’

Click the Link Above to read and/or download PDF File (1.78 MB)

.

However … and especially since the Workshop had been organized by IRUSE (the ‘SE’ standing for ‘Sustainable Engineering’) … it was indeed very strange to have to clarify the following points, among others:

1.   The Minimum Life Cycle for a Sustainable Building is 100 Years … not 50 or 60 years !

2.   Future Research Collaboration should be targeted at the multi-aspect ‘Sustainability Agenda’.  The word ‘green’ (where only environmental aspects of sustainability are considered) should be actively discouraged, if not banned entirely !

3.   With regard to Good Indoor Air Quality (IAQ) … two high-level performance indicators which have been developed with the aim of protecting human health, and are both now referenced in International Standard ISO 21542: ‘Building Construction – Accessibility & Usability of the Built Environment’ … are …

      –   Radon Activity (incl. Rn-222, Rn-220, RnD) in a building should, on average, fall within the range of 10 Bq/m3 to 40 Bq/m3, but should at no time exceed 60 Bq/m3 ;

      –   Carbon Dioxide (CO2) Concentrations in a building should not significantly exceed average external levels – typically within the range of 300 parts per million (ppm) to 500 ppm – and should at no time exceed 800 ppm.

.

Galway University’s New Engineering Building

Concerning the substantive difference in meaning and scope between ‘sustainable’ and ‘green’ … there is, perhaps, no better way to illustrate this difference than to observe the atrocious ‘Accessibility-for-All’ Performance (Accessibility for People with Activity Limitations !) of the critically acclaimed (?!?) and award winning (?!?) New Engineering Building in Galway University … which flaunts its ‘über-green’ credentials …

Galway University's New Engineering Building - Inadequate Accessibility-for-All (1)

Galway University's New Engineering Building - Inadequate Accessibility-for-All (2)

Galway University's New Engineering Building - Inadequate Accessibility-for-All (3)

Galway University's New Engineering Building - Inadequate Accessibility-for-All (4)

Galway University's New Engineering Building - Inadequate Accessibility-for-All (5)

Can you believe what’s in those photographs ??   More importantly … can you believe what’s not in those photographs ????   In such a recently completed building … “incredible” is the only answer to both questions.

.

Under International Law … lack of accessibility, or inadequate accessibility, to the social, built, virtual and economic environments … IS a denial and infringement of the basic human rights of people with activity limitations.  It also limits, needlessly and unnecessarily, the numbers of potential users of those environments … which makes no sense at all.

My strong recommendation to Galway University … is to immediately commission a Competent Accessibility Consultant to give the university campus a thorough going over !   You are failing the campus user population … the local community in Galway … and Irish society generally.

My even stronger recommendation to the Architects for the New Engineering BuildingRMJM Architects (Robert Matthew Johnson-Marshall) in Scotland, and Taylor Architects in Ireland … is to always commission a Competent Accessibility Consultant on all of your projects … small, medium and large … because you haven’t a bull’s notion about this important dimension of building performance !!

And remember folks … Accessibility has been clearly specified in the new International Standard ISO 21542 as including … ‘access to buildings, circulation within buildings and their use, egress from buildings in the normal course of events, and evacuation in the event of an emergency’.

.

.

END

 

Enhanced by Zemanta

BER Certificates, Energy Efficiency & Climate Change (II)

2009-02-23:  The World Business Council for Sustainable Development (WBCSD) has identified buildings as one of the five main users of energy where ‘megatrends’ are needed to transform global energy efficiency in the immediate short term, and so meet the daunting challenge of Climate Change Adaptation.  They account for 40% of primary energy (primary energy includes the energy required to generate, transmit and distribute electricity, as well as energy directly consumed on site) in most developed countries, and consumption is rising. 

                         … 2007 WBCSD Energy Efficiency in Buildings (EEB) Project

 

 

If you find that you are not responding emotionally to that … please leave your computer immediately and take a cold shower !   When you return, check out how far adrift Ireland is – even on paper – in meeting its legally binding 1997 Kyoto Protocol (UNFCCC) responsibilities.  After 2012, the European Union’s 2020 Targets will be in a different league altogether.

 

Let there be do doubt, therefore, that over the next few years … nothing less than a complete cultural shift will be necessary throughout the European Construction Sector – and this very much includes Ireland – beginning with all research and design disciplines and extending right across to any person who works on a construction site or has any part to play in managing, maintaining or servicing a building.

 

 

 

Burden Sharing in the Built Environment

 

Separate Energy Efficiency Strategies will be required to vastly improve the energy performance of:

         existing buildings … onto which many energy efficiency measures can be successfully grafted … but they will not be cheap, and they will not be 100% effective ;

         buildings of historical, architectural or cultural importance … the integrity of which must be protected ;   and

         new buildings, which must therefore carry the major burden.

 

In addition … if we fully value the Agricultural Industry in Ireland, the burden to be carried by New Buildings may have to be far heavier.

 

 

 

Suggested Building Energy Efficiency Targets in Ireland to 2020

 

From the Beginning of 2012, i.e. after an Essential Transition Period involving extensive re-education and up-skilling, accompanied by ‘attractive’ incentives …

         Require all New Buildings to achieve a Minimum Building Energy Rating (BER) of ‘A1’ … indicating a Primary Energy Consumption less than or equal to 25 kWh/m2/yr.  And require 40% of Primary Energy Consumed to be, directly or indirectly, from Renewable Energy Sources ;

         Require all Existing Buildings to achieve a Minimum Building Energy Rating (BER) of ‘B1’ … indicating a Primary Energy Consumption less than or equal to 100 kWh/m2/yr.  And require 15% of Primary Energy Consumed to be, directly or indirectly, from Renewable Energy Sources.  Retain Incentive Measures to achieve better performance with regard to energy efficiency and/or renewable energies ;

         Require Buildings of Historical, Architectural or Cultural Importance to achieve a Minimum Building Energy Rating (BER) of ‘C1’ … indicating a Primary Energy Consumption less than or equal to 175 kWh/m2/yr.  Retain Incentive Measures to achieve better energy efficiency performance.  No legal requirements or incentives with regard to Renewable Energies should apply to Buildings of Historical, Architectural or Cultural Importance.

 

From the Beginning of 2015

         Require all New Buildings to be ‘Positive Energy Buildings’ (see below) ;

         Require all Existing Buildings to achieve a Minimum Building Energy Rating (BER) of ‘A2’ … indicating a Primary Energy Consumption less than or equal to 50 kWh/m2/yr.  And require a Positive Energy Contribution of 25 kWh/m2/yr to be from renewable Energy Systems installed in the building ;

         Require Buildings of Historical, Architectural or Cultural Importance to achieve  a Minimum Building Energy Rating (BER) of ‘B1’ … indicating a Primary Energy Consumption less than or equal to 100 kWh/m2/yr.  Retain Incentive Measures to achieve better energy efficiency performance.  No legal requirements or incentives with regard to Renewable Energies shall apply to Buildings of Historical, Architectural or Cultural Importance.

 

 

 

‘Effective’ Technical Control of Construction & Post-Occupation Buildings

 

Any proposed Building Energy Efficiency/Conservation and Renewable Energy Improvements must take place in a legal environment of stringent control during construction (by competent Local Authority Building Controllers and/or Independent Technical Controllers) and rigorous post-construction energy performance monitoring (using Long Wave Infra-Red Thermal Imagery, in conjunction with building roof and external wall Air Seepage Tests).  Observation of post-occupation building energy performance will also be necessary.  Introduce mandatory 5-Yearly Energy Surveying of Buildings.

 

 

 

The Paradigm for New Buildings – A ‘Positive Energy’ Return

 

Primary Energy Consumption is less than or equal to 15 kWh/m2/yr.  Renewable Energy & Heating Systems then contribute a reliable quantity of energy, per year, which covers the following:

         the Building’s Primary Energy Consumption ;

         an Energy Efficiency Degradation Factor which takes account of the degradation in energy efficiency normally expected during the life cycle of renewable energy and heating systems installed in the building (the rate of degradation will depend on the quality of maintenance and servicing) … and caused by wasteful patterns of building management and/or use ;

         the energy consumed by Private Transport associated with the building ;

         an Energy Return to an Intelligent District or Regional Grid exceeding, by a whole number multiple determined by reference to local conditions, the total energy consumed by the Building (including its Energy Efficiency Degradation Factor) and any associated Private Transport.

 

Uniquely, this more practical elaboration of the innovative concept of Positive Energy Buildings considers life cycle energy efficiency degradation.

 

.

 

.

 

END